ZPA

ZPA Meter TASMOTA Scripts - Electricity Reader WIFI

Please select the appropriate electricity meter model.
ZPA GH302 (SML)
 >D
 >B
 =>sensor53 r
 >M 1
 +1,3,s,0,9600,current,1
 1,77070100010800ff@1000,Reference,kWh,Total_in,0
 1,77070100020800ff@1000,feed-in,kWh,total_out,0
 #
ZPA GH305 (SML)
 >D
 >B
 =>sensor53 r
 >M 1
 +1,3,s,0,9600,SML,1
 1.77070100010800ff@1000,Total consumption,kWh,Total_in,3
 1,77070100020800ff@1000,Total feed-in,kWh,Total_out,3
 1,==h==================
 1.77070100100700ff@1,Actual load,W,Power_curr,0
 1,==h==================
 1,=m 9+10+11 @1,Currents L1+L2+L3,A,Curr_summ,3
 1,=m 12+13+14/#3 @1,Voltage L1+L2+L3/3,V,Volt_avg,3
 1,==h==================
 1.77070100240700ff@1,Consumption P1,W,Power_p1,2
 1.77070100380700ff@1,Consumption P2,W,Power_p2,2
 1,770701004c0700ff@1,Consumption P3,W,Power_p3,2
 1,=h ----
 1,770701001f0700ff@1,Current L1,A,Curr_p1,3
 1.77070100330700ff@1,Current L2,A,Curr_p2,3
 1.77070100470700ff@1,Current L3,A,Curr_p3,3
 1,=h ----
 1.77070100200700ff@1,Voltage L1,V,Volt_p1,3
 1.77070100340700ff@1,Voltage L2,V,Volt_p2,3
 1.77070100480700ff@1,Voltage L3,V,Volt_p3,3
 1,==h==================
 1.77070100510701ff@1,Phaseangle L2-L1,deg,phase_angle_L2_L1,0 
1.77070100510702ff@1,Phaseangle L3-L1,deg,phase_angle_L3_L1,0
 1.77070100510704ff@1,Phaseangle I/U L1,deg,phase_angle_L1,1
 1.7707010051070fff@1,Phaseangle I/U L2,deg,phase_angle_L2,1
 1.7707010051071aff@1,Phaseangle I/U L3,deg,phase_angle_L3,1
 1.770701000e0700ff@1,Frequency,Hz,Freq,1
 ;1,=h========UNKNOWN===========
 ;1,77070100000009FF@#,unknown1,,Power_Use_Sum,3
 ;1,77070100000000FF@#,unknown2,,Power_Use_Sum,3
 ;1,7707010060320101@#,unknown3,,Meter_id,0
 ;1,77010b0a01445a47@#,unknown4,,Meter_id,0
 ;1,77070100600100ff@#,unknown5,,Meter_id,0
 1,=h
 #