Please select the appropriate electricity meter model.
Values updated every 2-3 seconds - NT (off-peak tariff) and HT (main tariff) are read out
Iskra AM550
>D res=0 scnt=0 >B =>sensor53 r >F scnt+=1 switch scnt case 6 res=sml(1 0 300) res=sml(1 1 "2F3F210D0A") case 18 res=sml(1 1 "063035300D0A") case 20 res=sml(1 0 9600) case 80 scnt=0 ends >M 1 +1,3,o,0,9600,Counter,1 1,1-0:1.8.0(@1,reference,kWh,1-8-0,2 1,1-0:2.8.0(@1,feed-in,kWh,2-8-0,2 #
Iskra MT 174
>D >B ->sensor53 r >M 1 +1,3,o,0,300,MT174,4,100,2F3F210D0A,1 1.1-0:1.8.0*255(@1,Total Consumed,kWh,Total_in,3 1.1-0:2.8.0*255(@1,Total Delivered,kWh,Total_out,3 1.1-0:0.0.0*255(@#),Meter Number,,Meter_number,0 #
Iskra MT 175
>D >B ->sensor53 r >M 1 +1,3,s,16,9600,MT175,1 1.77070100010800ff@1000,consumption,kWh,E_in,3 1,77070100020800ff@1000,feed-in,kWh,E_out,3 1,77070100100700ff@1,current power,W,Power,0 1,=h-- 1.77070100240700ff@1,L1,W,L1,0 1.77070100380700ff@1,L2,W,L2,0 1.770701004C0700ff@1,L3,W,L3,0 1.77070100000009ff@#,Server_ID,,Server_ID,0 #
Iskra MT 175 Script with NT and HT
>D >B ->sensor53 r >M 1 +1,3,s,16,9600,MT175,1 1,77070100010800ff@1000,Consumption,kWh,E_in,1 1,77070100010801ff@1000,Consumption_HT,kWh,E_in_HT,1 1,77070100010802ff@1000,Consumption_NT,kWh,E_in_NT,1 1,77070100020800ff@1000,Feed-in,kWh,E_out ,1 1,77070100100700ff@1,current power,W,Power,18 1,=h-- 1.77070100240700ff@1,L1,W,L1,18 1.77070100380700ff@1,L2,W,L2,18 1.770701004C0700ff@1,L3,W,L3,18 1.77070100000009ff@#,Server_ID,,Server_ID,0 #
Iskra MT 176
>D >B ->sensor53 r >M 1 +1,3,s,16,9600,MT176,1 1.77070100010800ff@1000,consumption,kWh,E_in,3 1,77070100020800ff@1000,feed-in,kWh,E_out,3 1,77070100100700ff@1,current power,W,Power,0 1,=h-- 1.77070100240700ff@1,L1,W,L1,0 1.77070100380700ff@1,L2,W,L2,0 1.770701004C0700ff@1,L3,W,L3,0 1.77070100000009ff@#,Server_ID,,Server_ID,0 #
Iskra MT 382
>D res=0 scnt=0 >B =>sensor53 r >F scnt+=1 switch scnt case 6 res=sml(1 0 300) res=sml(1 1 "2F3F210D0A") case 18 res=sml(1 1 "063035300D0A") case 20 res=sml(1 0 9600) case 80 scnt=0 ends >M 1 +1,3,o,16,9600,MT382,1 1,1-0:1.8.0(@1,reference,kWh,1-8-0,2 1,1-0:2.8.0(@1,feed-in,kWh,2-8-0,2 1,1-0:1.7.0(@0.001,act. power,W,Power,3 #
Iskra MT 631
>D >B =>sensor53 r >M 1 +1,3,s,16,9600,MT631,1 1.77070100010800ff@1000,consumption,kWh,E_in,3 1,77070100020800ff@1000,feed-in,kWh,E_out,3 1,77070100100700ff@1,current power,W,Power,0 1,=h-- #
Iskra MT 681
>D >B =>sensor53 r >M 1 +1,3,s,16,9600,MT681,1 1.77070100010800ff@1000,consumption,kWh,E_in,3 1,77070100020800ff@1000,feed-in,kWh,E_out,3 1,77070100100700ff@1,current power,W,Power,0 1,=h-- 1.77070100240700ff@1,Current Consumption P1,W,Power_p1,0 1.77070100380700ff@1,Current Consumption P2,W,Power_p2,0 1.770701004c0700ff@1,Current Consumption P3,W,Power_p3,0 1.77070100000009ff@#,Service ID,,Meter_id,0 #
Iskra MT 691
>D >B =>sensor53 r >M 1 +1,3,s,16,9600,MT691,1 1.77070100010800ff@1000,consumption,kWh,E_in,3 1,77070100020800ff@1000,feed-in,kWh,E_out,3 1,77070100100700ff@1,current power,W,Power,0 1,=h-- 1.77070100000009ff@#,Service ID,,Meter_id,0 #
Leave a comment