Elster

Elster / Honeywell Meter TASMOTA Scripts - Electricity Reader WIFI

Magpie/Honeywell Meter Scripts
Magpie / Honeywell AS1440
 >D
 scnt=0
 res=0
 >B
 =>sensor53 r
 >F
 scnt+=1
 switch scnt
 case 3
 res=sml(1 0 300)
 res=sml(1 1 "2F3F210D0A")
 case 20
 res=sml(1 1 "063035300D0A")
 case 23
 res=sml(1 0 9600)
 case 60
 scnt=0
 ends
 >M 1
 +1,3,o,16,9600,AS1440,1
 1,1.7.0(@0.001,Power In,W,power_in,0
 1,1.8.1(@1,Total In,kWh,Total_in,3
 1,2.7.0(@0.001,Power Out,W,power_out,0
 1,2.8.1(@1,Total Out,kWh,Total_out,3
 1,=h--
 1.1-1:1.8.1(@1,Total In HT,kWh,E_inHT,3
 1.1-1:1.8.2(@1,Total In NT,kWh,E_inNT,3 
1.1-1:2.8.1(@1,Total Out HT,kWh,E_outHT,3
 1.1-1:2.8.2(@1,Total Out NT,kWh,E_outNT,3
 #
Magpie / Honeywell AS2020
 >D
 >B
 ->sensor53 r
 >M 1
 +1,3,s,16,9600,AS2020,1
 1.77070100010800ff@1000,consumption,kWh,E_in,3
 1,77070100020800ff@1000,feed-in,kWh,E_out,3
 1,77070100100700ff@1,current power,W,Power,0
 1,=h--
 1.77070100600100ff@#,Server ID,,Value,0
 #
Magpie / Honeywell AS3500
 >D
 scnt=0
 res=0
 >B
 =>sensor53 r
 >F
 scnt+=1
 switch scnt
 case 3
 res=sml(1 0 300)
 res=sml(1 1 "2F3F210D0A")
 case 20
 res=sml(1 1 "063035300D0A")
 case 23
 res=sml(1 0 9600)
 case 60
 scnt=0
 ends
 >M 1
 +1,3,o,16,9600,AS3500,1
 1.1-1:1.8.0(@1,consumption,kWh,E_in,3
 1,1-1:1.7.0(@0.001,act. power,W,Power,3
 1,1-1:21.7.0(@0.001,Leistungs L1,W,Power_L1,3
 1.1-1:41.7.0(@0.001,Power L2,W,Power_L2,3
 1.1-1:61.7.0(@0.001,Power L3,W,Power_L3,3
 1,1-1:0.0.0(@1,SN,1,SN,0
 #
Elster T510
 >D
 res=0
 scnt=0
 >B
 ->sensor53 r
 >F
 scnt+=1
 switch scnt
 case 6
 res=sml(1 0 300)
 res=sml(1 1 "2F3F210D0A")
 case 18
 res=sml(1 1 "063035300D0A")
 case 20
 res=sml(1 0 9600)
 case 50
 scnt=0
 ends
 >M 1
 +1,3,o,16,9600,T510,1
 1,0.0.0(@1,Meter_number,,Meter_number,0
 1,1.8.0(@1,meter reading,kWh,Total_in,3
 1,21.7.0(@0.001,Power Phase 1,W,Power_L1,0
 1,41.7.0(@0.001,Power Phase 2,W,Power_L2,0
 1,61.7.0(@0.001,Power Phase 3,W,Power_L3,0
 1,=m 4+5+6 @1,Leistungs,W,Power_total,0
 1,31.7.0(@1,Current phase 1,A,Current_L1,2
 1,51.7.0(@1,Current phase 2,A,Current_L2,2
 1,71.7.0(@1,Current phase 3,A,Current_L3,2
 #

Reading next

Leave a comment