Please select the appropriate electricity meter model.
E220: To read the “current performance”, the extended data set must be activated in the user menu E320: To activate the extended information on the Landis + Gyr E320 meter, you must activate the extended display via PIN and the information via light interface. These can be found in two different menu items. Use a flashlight to activate the setting via light interface to activate ZMB120: This meter may require a PIN to unlock the current power consumption - ask your provider.
Landis + Gyr E220
>D >B =>sensor53 r >M 1 +1,3,s,16,9600,E220,1 1.77070100010800ff@1000,consumption,kWh,E_in,3 1,77070100020800ff@1000,feed-in,kWh,E_out,3 1,77070100100700ff@1,current power,W,Power,0 1,=h-- 1.77070100600100ff@#,Server ID,,Meter_Number,0 #
Landis + Gyr E230
>D >B =>sensor53 r >F scnt+=1 switch scnt case 6 res=sml(1 0 300) res=sml(1 1 "2F3F210D0A") case 18 res=sml(1 1 "063035300D0A") case 20 res=sml(1 0 9600) case 50 scnt=0 ends >M 1 +1,3,o,16,9600,E230,1 1,1.8.0(@1,Total Consumed,kWh,Total_in,3 1,2.8.0(@1,Total Delivered,kWh,Total_out,3 1,16.7.0(@1,Current power,kW,Power_in,2 1,C.1.0(@1,ServerID,,Meter_number,0 #
Landis + Gyr E320
>D >B =>sensor53 r >M 1 +1,3,s,16,9600,E320,1 1.77070100010800ff@1000,consumption,kWh,E_in,3 1,77070100020800ff@1000,feed-in,kWh,E_out,3 1,77070100100700ff@1,current power,W,Power,0 1,=h-- 1.77070100600100ff@#,Server ID,,Meter_Number,0 #
Landis + Gyr E350
>D scnt=0 res=0 >B ->sensor53 r >F scnt+=1 switch scnt case 6 res=sml(1 0 300) res=sml(1 1 "2F3F210D0A") case 18 res=sml(1 1 "063035300D0A") case 20 res=sml(1 0 9600) case 50 scnt=0 ends >M 1 +1,3,o,16,9600,E350,1 1,1.8.0(@1,Total Consumed,kWh,Total_in,3 1,2.8.0(@1,Total Delivered,kWh,Total_out,3 1,16.7(@1,Current power,kW,Power_in,2 1,C.1.0(@1,ServerID,,Meter_number,0 #
Landis + Gyr E650
>D res=0 scnt=0 >F scnt+=1 switch scnt case 6 res=sml(1 0 300) res=sml(1 1 "2F3F210D0A") case 18 res=sml(1 1 "063034300D0A") res=sml(1 0 4800) case 200 scnt=0 ends >M 1 +1,3,o,0,4800,E650,1 1.1-1:1.8.0(@1,consumption,kWh,1-8-0.3 1.1-1:1.8.1(@1,consumption NT,kWh,1-8-1.3 1,1-1:1.8.2(@1,Consumption HT,kWh,1-8-2,3 1,1-1:2.8.0@1,feed-in,kWh,2-8-0,3 1,1-1:2.8.1(@1,Feed-in HT,kWh,2-8-1,3 1,1-1:2.8.2(@1,Feed-in NT,kWh,2-8-2,3 1.1-1:1.5.0(@1,power_IN,kW,1-5-0.3 1.1-1:2.5.0(@1,power_OUT,kW,1-5-0.3 1.1-1:21.5.0(@1,power_L1,kW,21-5-0.3 1.1-1:41.5.0(@1,power_L2,kW,41-5-0.3 1.1-1:61.5.0(@1,power_L3,kW,61-5-0.3 1.1-1:32.7.0(@1,voltage_L1,V,32-7-0.2 1.1-1:52.7.0(@1,voltage_L2,V,52-7-0.2 1.1-1:72.7.0(@1,voltage_L3,V,72-7-0.2 1,1-1:31.7.0(@1,current_L1,A,31-7-0,3 1,1-1:51.7.0(@1,current_L2,A,51-7-0,3 1,1-1:71.7.0(@1,current_L3,A,71-7-0,3 1,1-1:91.7.0(@1,current_N,A,91-7-0,3 #
Landis + Gyr ZMB120
>D res=0 scnt=0 >B =>sensor53 r >F scnt+=1 switch scnt case 6 res=sml(1 0 300) res=sml(1 1 "2F3F210D0A") case 18 res=sml(1 1 "063035300D0A") case 20 res=sml(1 0 9600) case 50 scnt=0 ends >M 1 +1,3,o,0,9600,ZMB120,1 1,1.8.0(@1,HT+NT meter reading,kWh,Total_in,3 1,1.8.1(@1,HT,kWh,HT_Total_in,3 1,1.8.2(@1,NT,kWh,NT_Total_in,3 1,==h==================== 1,36.7.0(@1,Power_L1,kW,kW_L1,2 1.56.7.0(@1,Power_L2,kW,kW_L2,2 1,76.7.0(@1,Power_L3,kW,kW_L3,2 1,16.7.0(@1,Σ_L1+L2+L3,kW,kW_L1+L2+L3,2 1,==h==================== 1,31.7.0(@1,Current_L1,A,I_L1,2 1,51.7.0(@1,Current_L2,A,I_L2,2 1,71.7.0(@1,Current_L3,A,I_L3,2 1,==h==================== 1,0.0.1(@1,Meter_number,,Meter_number,0 1,0.9.1(@#),timestamp,clock,time-stamp,0 #
Landis + Gyr ZMD120
>D scnt=0 res=0 >B =>sensor53 r >F scnt+=1 switch scnt case 6 res=sml(1 0 300) res=sml(1 1 "2F3F210D0A") case 18 res=sml(1 1 "063034300D0A") case 20 res=sml(1 0 4800) case 50 scnt=0 ends >M 1 +1,3,o,0,4800,ZMD120,1 1,1.8.1(@1,Consumption HT,kWh,EinHT,3 1,1.8.2(@1,Consumption NT,kWh,EinNT,3 1,==h==================== 1,2.8.1(@1,Feed-in HT,kWh,EoutHZ,3 1,2.8.2(@1,Feed-in NT,kWh,EoutNT,3 #
Landis + Gyr T550
>D scnt=0 res=0 >B ->sensor53 r >F scnt=scnt+1 switch scnt ;start after 1.6 seconds (16 x 100ms) case 16 ;set transfer speed to 300 baud res=sml(1 0 300) ;trigger meter by sending 40 times 'NUL' res=sml(1 1 "0000000000000000000000000000000000000000") res=sml(1 1 "0000000000000000000000000000000000000000") ;followed by '/?! CR LF' res=sml(1 1 "2F3F210D0A") case 24 res=sml(1 1 "063033300D0A") ;set transfer speed to 2400 baud res=sml(1 0 2400) ;restart sequence after 10 minutes (6000 x 100 ms) case 6000 scnt=0 ends >M 1 +1,3,o,0,2400,T550,1 1,=so2,0 1,6.8(@1,meter reading,MWh,mwh_count,3 1,6.6(@1,Max. heating output,kWh,kwh_max_heatperf,1 1,6.26(@1,throughput,m³,m3_throughput,2 1,6.33(@1,Max. throughput per h,m³h,m3h_max_throughput,3 1,9.4(@1,Max. Temp. F/R run,°C,c_max_temp_fb,1 #